Outdoor Fiber Patch Cord

  • 3m  LC UPC to LC UPC Simplex OS2 Single Mode 7.0mm LSZH FTTA Outdoor Fiber Patch Cable

    3m LC UPC to LC UPC Simplex OS2 Single Mode 7.0mm LSZH FTTA Outdoor Fiber Patch Cable

    LC-LC DX CABLE

    Specification

    1. GYFJH Cable

    1.1 Structure:

    FTTA

     

    1.2 Application

    Mainly used in wireless base station horizontal and vertical cabling

    1.3 Features

    1, Good mechanical and environmental characteristics;

    2, Flame retardant characteristics meet the requirements of relevant standards;

    3, The mechanical characteristics of jacket meet the requirements of relevant standards;

    4, Soft, flexible, water blocked, UV resistant, easy to lay and splice, and with big capacity data transmission;

    5, Meet various requirements of market and clients

    1.4 Cable Parameters

    Fiber Count Cable Dimension

    mm

    Cable Weight

    kg/km

    Tensile

    N

    Crush

    N/100mm

    Min. Bend Radius

    mm

    Range of Temperature

     

    Long Term Short Term Long Term Short Term Dynamic Static
    2 7.0 42.3 200 400 1100 2200 20D 10D -30-+70
    Note: 1. All the values in the table, which are for reference only, are subject to change without notice;

    2. The cable dimension and weight are subject to the simplex cable of 2.0 outer diameter;

    3. D is outer diameter of the round cable;

    1. one single mode  fiber 

    Item

    Unit

    Specification

    Attenuation

    dB/km

    1310nm≤0.4

    1550nm≤0.3

    Dispersion

    Ps/nm.km

    1285~1330nm≤3.5

    1550nm≤18.0

    Zero dispersion wavelength

    Nm

    1300~1324

    Zero dispersion slope

    Ps/nm.km

    ≤0.095

    Fiber cutoff wavelength

    Nm

    ≤1260

    Mode field diameter

    Um

    9.2±0.5

    Mode field concentricity

    Um

    <=0.8

    Cladding diameter

    um

    125±1.0

    Cladding non-circularity

    %

    ≤1.0

    Coating/cladding concentricity error

    Um

    ≤12.5

    Coating diameter

    um

    245±10

    bending, dependence        induced attenuation

    1550nm,  1turns,32mm diameter  100rums,60mm diameter

    ≤0.5 db

    Proof test

    kpsi

    ≥100

     

    1. Connector Specification

    ITEM

    PARAMETER

    Connector type

    DLC/UPC .  FC/UPC

    Insertion Loss

    <=0.3db

    Return Loss

    >=50db

    Fiber mode

    Single mode 9/125

    Operating wavelength

    1310nm, 1550nm

    Test wavelength

    1310nm, 1550nm

    Repeatability

    <=0.1

    Interchangeability

    <=0.2dB

    Durability

    <=0.2dB

    Fiber Length

    1m, 2m….. any length optional.

    Length and tolerance

    10cm

    Operating Temperature

    -40C ~ +85C

    Storage Temperature

    -40C ~ +85C

  • FTTA jumper-PDLC-DLC Fiber Outdoor Patch cord

    FTTA jumper-PDLC-DLC Fiber Outdoor Patch cord

    Good mechanical and environmental characteristics;

    Flame retardant characteristics meet the requirements of relevant standards;

    The mechanical characteristics of jacket meet the requirements of relevant standards;

    Soft, flexible, water blocked, UV resistant, easy to lay and splice, and with big capacity data transmission;

    Meet various requirements of market and clients。